MENU
[home]
[people]
[projects]
[publications]
[movies]
[links]
|
|
Welcome to the Duke University
Ultrasound Transducer Group
Professor Stephen Smith
Publications
- Emery CD, Swartz JC, Casey HC, Jr., and Smith SW, Optoelectronic transmitter for medical
ultrasound transducers, IEEE Trans. on Ultrason., Ferroelectrics and Freq. Control, UFFC-42, 188-199, 1995.
- Smith SW, Lopath PA, Adams DA, and Walcott GP, Cardiac ultrasound phantom using a porcine
heart model, Ultrasound in Med. and Biol. 21, 693-697, 1995.
- Goldberg RL and Smith SW, "Optimization of SNR for multi-layer PZT transducers", Ultrasonic
Imaging, 17, 95-113,1995.
- Goldberg RL and Smith SW, Transducers for medical ultrasound, in Biomedical Engineering
Handbook, J.D. Bronzino, ed, CRC Press Boca Raton, FL, 1077-1092, 1995 .
- Ries LL and Smith SW, "Phase aberration correction in two dimensions using a deformable array
transducer", Ultrasonic Imaging, 17, 227-247, 1995.
- Goldberg RL, Emery CD and Smith SW, "Hybrid multi/single layer array transducers for
increased signal to noise ratio," IEEE Trans. Ultrason. Ferro. Freq. Control., 44, 315-325, 1997.
- Goldberg RL, Jurgens ML, Henriquez C, Vaughan D, Mills DM and Smith SW, "Modeling of
piezoelectric multilayer ceramics using finite element analysis", IEEE Trans Ultras. Ferro and Freq.
Control, 44, 1204-1211, 1997.
- Davidsen RF and Smith SW, "Two-dimensional arrays for medical ultrasound using multilayer flexible
circuit interconnection", IEEE Trans Ultras. Ferro and Freq. Control, 45, 338-348,1998.
- Ries LL and Smith SW, "Phase aberration correction in two dimensions with an integrated deformable
actuator/transducer", IEEE Trans Ultras. Ferro and Freq. Control, 44, 1366-1375, 1997.
- Emery CD and Smith SW, "Improved signal to noise ratio in hybrid 2-D arrays: experimental
confirmation", Ultrasonic Imaging, 19, 1997 .
- Davidsen RE and Smith SW, "Multiplexed 2-D array for real time volumetric ultrasound scanning"
Ultrasonic Imaging, 19, 235-250, 1997.
- Ries LL and Smith SW, "Finite element analysis of a deformable array transducer", IEEE Trans Ultras.
Ferro and Freq. Control, 46, 1352-1363, 1999.
- Ota T, Fleishman CE, Stetten G, Ohizama CJ, Smith SW, Castellucci JB, Kisslo J and von
Ramm OT, "Volume measurements using high speed volumetric scanning, real time three dimensional
echocardiography: in vitro validation" submitted to Circulation.
- Emery CD, Casey HC and Smith SW "Ultrasonic imaging using optoelectronic transmitters",
Ultrasonic Imaging, 19, 93-111,1997.
- Light ED, Davidsen RE, Fiering JO, Hruschka TA, and Smith SW, "Progress in 2-D arrays for
real time volumetric imaging", Ultrasonic Imaging , 20, 1-16, 1998.
- Emery CD and Smith SW, "Ultrasound imaging using a 5 MHz Multilayer/Single Layer Hybrid Array for
Increased Signal to Noise Ratio", IEEE Trans Ultras. Ferro and Freq. Control, 46, 1101-1119, 1999.
- Mills DM and Smith SW, "Hybrid multilayer PZT/polymer composite transducer to increase signal to
noise ratio and bandwidth for medical ultrasound", IEEE Trans Ultras. Ferro and Freq. Control, 46, 961-971,
1999.
- Yen JT and Smith SW "Sparse 2D array design for real time rectilinear volumetric imaging", IEEE
Trans Ultras. Ferro and Freq. Control, 47, 93-110,2000
- Fiering JO, Hultman P, Lee W, Light ED and Smith SW, "High density flexible interconnect
for two-dimensional ultrasound arrays", IEEE Trans Ultras. Ferro and Freq. Control, 47, 764-770, 2000
- Zara JM, Bobbio SM, Goodwin-Johansson S, and Smith SW, "Intracardiac ultrasound scanner using a
micromachine (MEMS) actuator", IEEE Trans Ultras. Ferro and Freq. Control, 47, 984-993, 2000.
- Mills DM and Smith SW, "Multi-layered PZT/Polymer composites to increase signal to noise ratio
and resolution for medical ultrasound transducers part II: thick film technology", IEEE Trans Ultras. Ferro
and Freq. Control, 49, 1005-1014, 2002.
- Mills, D.M. and Smith, S.W., "Finite element comparison of single crystal vs. multi-layer composite
arrays for medical ultrasound", IEEE Trans Ultras. Ferro and Freq. Control, 49, 1015-1020, 2002.
- Gentry KL, Zara JM, Bu SD, Eom CB, and Smith SW, Thick film sol gel PZT transducer using dip coating,
(submitted to IEEE Trans Ultras. Ferro and Freq. Control).
- Light ED, Idriss SF, Wolf PD and Smith SW, "Real Time 3D Intracardiac Echocardiography",
Ultrasound in Med and Biol., 27, 1177-1183, 2001.
- Lee W and Smith SW, "Intracardiac catheter 2D arrays on a silicon substrate", IEEE Trans Ultras. Ferro
and Freq. Control, 49, 415-425, 2002.
- Yen JT and Smith SW "Real time rectilinear volumetric imaging", IEEE Trans Ultras. Ferro and Freq.
Control, 49, 114-124, 2002.
- Smith, SW, Light, ED, Idriss, SF, and Wolf, PD, "Feasibility study of real time three dimensional
intracardiac echocardiography", Pacing and Clin. Electrophys. 25, 351-357, 2002.
- Light ED, Idriss SF, and Wolf PD, Smith SW, "Real time three dimensional Doppler intracardiac
echocardiography", Ultrasonic Imaging, 24, 36-46, 2002
- Yen J.T. and Smith SW "Real time rectilinear volumetric imaging with a periodic array", Ultrasound
in Medicine and Biology, 7, 923-931, 2002.
- Zara JM, and Smith SW, "A micromachine high frequency scanner using photolithographic fabrication",
IEEE Trans Ultras. Ferro and Freq. Control, 49, 947-958, 2002.
- Zara JM, and Smith SW, "Optical scanner using a micromachine actuator", Sensors and Actuators A:
Physical, 102, 176-184, 2002.
- Smith, SW, Booi RC, Light, ED, Merdes CL and Wolf, PD, "Guidance of cardiac pacemaker leads using real
time 3D ultrasound: feasibility studies", Ultrasonic Imaging, 24, 119-128, 2002.
- Lee W, Idriss, SF, and Wolf, PD,Smith, SW, "Dual lumen transducer probes for real time 3D
interventional cardiac ultrasound", Ultrasound in Medicine and Biology, 29, 1297-1304, 2003.
- Zara JM, Yazdanfar S, Rao KD, Izatt JA, Smith SW, "Electrostatic micromachine scanning mirror for
optical coherence tomography", Optics Letters, 28, 628-630, 2003.
- Yen JT and Smith SW "Real time rectilinear volumetric imaging with receive mode multiplexers",
IEEE Trans. Ultras. Ferro and Freq. Control 30, 216-226, 2004.
- Pua EC, Yen JT and Smith SW, "Real-time cylindrical curvilinear 3-D ultrasound imaging",
Ultrasonic Imaging, 25, 109-121, 2003.
- Gentry KL and Smith SW, "Integrated Catheter for 3-D Intracardiac Echocardiography and Ultrasound
Ablation", IEEE Trans. Ultras. Ferro. And Freq. Control 51, 800-808, 2004.
- Lee W, Idriss SF, Wolf PD, Smith SW, "A miniaturized catheter 2D array for real time 3D
intracardiac echocardiography", IEEE Trans. Ultras. Ferro. And Freq. Control 51, 1334-1346, 2004.
- Smith SW, Chu K, Idriss SF, Ivancevich NM, Light ED, Wolf PD, "Feasibility Study: Real time 3D
ultrasound imaging of the brain", Ultras. Med. Biol. 30, 1365-1371.
- Light ED and Smith SW, "Two dimensional arrays for real time 3D intravascular ultrasound", Ultrasonic
Imaging, 26, 115-128, 2004.
- Fronheiser MP, Wolf PD, Idriss SF, Nelson RC, Lee W, Smith SW, "Real-time 3D color flow Doppler for
guidance of vibrating interventional devices", Ultrasonic Imaging, 26, 71-84, 2004.
- Pua EC, Idriss SF, Wolf PD, Smith SW, "Real-time 3D transesophageal echocardiography", Ultrasonic Imaging, 26, 217-232, 2004.
- Gentry KL, Sachedina N, Smith, SW "Catheter ultrasound phased-array transducers for thermal ablation: a feasibility study", Ultrasonic Imaging, 27, 89-100, 2005.
- Light ED, Idriss SF, Sullivan KF, Wolf PD, Smith SW, "Real-time 3D laparoscopic ultrasonography", Ultrasonic
Imaging, 27, 129-144, 2005.
- Gentry KL, Palmeri ML, Sachedina N, Smith, SW "Finite-element analysis of temperature rise and lesion formation from catheter ultrasound ablation transducers", IEEE Trans. Ultras. Ferro. And Freq. Control, 52, 1713-1721, 2005.
- Fronheiser MP, Light ED, Idriss SF, Wolf PD, Smith SW, "Real-time 3D ultrasound with multiple transducer arrays", IEEE Trans. Ultras. Ferro. And Freq. Control, 53, 1432-1439, 2006.
- Ivancevich N, Dahl JD, Trahey GE, Smith SW, "Phase-aberration correction with a 3_D ultrasound scanner: feasibility study", IEEE Trans. Ultras. Ferro. And Freq. Control, 53, 100-105, 2006.
- Pua EC, Fronheiser MP, Noble JR, Light ED, Wolf PD, von Allmen D, Smith SW, "3-D ultrasound guidance of surgical robotics: a feasibility study", IEEE Trans. Ultras. Ferro. And Freq. Control, 53, 1999-2008, 2006.
- Noble JR, Fronheiser MP, Smith SW, "Real-time Stereo 3D Ultrasound", Ultrasonic Imaging, 28, 245-254, 2006.
- Pua EC, Qiu Y, Smith SW, "Integrated Endoscope for Real-Time 3D Ultrasound Imaging and Hyperthermia: Feasibility Study", Ultrasonic Imaging, 29, 1-14, 2007.
- Fronheiser MP and Smith SW, "Analysis of a Vibrating Interventional Device to Improve 3-D Colormark Tracking", IEEE Trans. Ultras. Ferro. And Freq. Control, vol. 54, pp. 1700-1707, 2007.
- Light ED, Srinivasan M, Wolf PD, Smith SW, "Real-Time 3-D Intracranial Ultrasound with an Endoscopic Matrix Array Transducer", Ultrasound in Medicine and Biology, vol. 33, pp. 1277-1284, 2007.
- Pua EC, Idriss SF, Wolf PD and Smith SW. "Real-Time Three Dimensional Transesophageal Echocardgiography for Guiding Interventional Electrophysiology: Feasibility Study." Ultrasonic Imaging, 29, 159-188, 2007.
- Klein SM, Fronheiser MP, Reach J, Nielsen KC and Smith SW. " Piezoelectric vibrating Needle and Catheter for Enhancing Ultrasound-Guided Peripheral Nerve Blocks." Anethesia & Analgesia, vol. 105, No. 6, 1858-1860, 2007.
- Ramireddy A, light ED and Smith SW." Ultrasound Probe with Integrated ECG Lead: Feasibility Study" Ultrasonic Imaging, 29, 195-198, 2007.
- Whitman J, Fronheiser MP, Ivancevivh NM and Smith SW. "Autonomous Surgical Robotics Using 3-D Ultrasound Guidance: Feasibility Study." Ultrasonic Imaging, 29, 213-219, 2007.
- Whitman J, Fronheiser MP and Smith SW. "Using 3-D Ultrasound Guidance of Surgical Robots Using Catheter Transducers: Feasibility Study ." IEEE Trans. Ultras. Ferro. And Freq. Control, vol. 55, pp. 1143-1145, 2008.
- Fronheiser MP, Idriss SF, Wolf PD and Smith SW. "Vibrating Interventional Device Detection Using Real-Time 3-D Color Doppler." IEEE Trans. Ultras. Ferro. And Freq. Control, vol. 55, pp. 1355-1362, 2008.
*Note: If documents do not automatically open in your web browser, right click on the title name and save the PDF file to your computer using "save target as". All documents should be viewable using Adobe Acrobat Reader.
Copyright
Information:
This material is presented to ensure timely dissemination of scholarly
and technical work. Copyright and all rights therein are retained by authors
or by other copyright holders. All persons copying this information are
expected to adhere to the terms and constraints invoked by each author's
copyright. In most cases, these works may not be reposted without the explicit
permission of the copyright holder.
IEEE Copyright Notice
Copyright, © 1995-2001 IEEE. The IEEE owns the copyright to all
material included below that is published by the IEEE. Personal use of
this material is permitted. However, permission to reprint/republish this
material for advertising or promotional purposes or for creating new collective
works for resale or redistribution to servers or lists, or to reuse any
copyrighted component of this work in other works must be obtained from
the IEEE. For more information please refer to the IEEE policies for the
new publishing and communications technologies. Request permissions from: Manager, Copyrights and Permissions / IEEE Service Center / 445 Hoes Lane
/ P.O. Box 1331 / Piscataway, NJ 08855-1331, USA. Telephone: + Intl. 908-562-3966.
AIP Copyright Notice
Copyright, © 1995-2001 American Institute of Physics. Articles
published by AIP may be downloaded for personal use only. Any other use